Skip to content Skip to main navigation Skip to footer

Challenger 10 Cheat Sheet and User Manual

Tecom Challenger V10 Cheat Sheet

Find a list of common tasks that you become almost an everyday task when using the Challenger V10 system.

  • Default Installer Code: 4346
  • Installer User Number: 50
  • How to Change Installer Code: Press Menu -> Installer Code -> 14 Enter -> 3 Enter -> 5o Enter – Enter through Menu until “Pin Code” enter new code
  • Installer Menu: Press Menu -> Installer Code -> 19 Enter
  • Set Security Password: Press Menu -> Installer Code -> 19 Enter -> 29 Enter -> Enter New Security Password
  • Date and Time Menu: Press Menu -> Installer Code -> 15 Enter
  • User Menu: Press Menu -> Installer Code -> 14 Enter
  • Change “Custom Message” Text on Keypads (LCD RAS): Press Menu -> Installer Code -> 19 Enter -> 26 Enter -> Enter New Custom Message

Common Input Types.

  • Secure Alarm – Input Type 2: Alarm triggers only when area is armed.
  • Entry Exit No Seal Check – Input Type 13: Allows entry and exit time on the zone and does not check status at arming. Eg. PIR at entry door.
  • 24 Hour Alarm – Input Type 5: Alarm triggers at anytime – even when area is disarmed.
  • 24 Hour Non Latching  Alarm – Input Type 29: Alarm generates anytime. The alarm resets automatically when the input seals.

Challenger 10 System Numbering

 

Challenger 10 User Menu

 

Challenger Installer Menu